Ohaus I150-S Indicator Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Balanças Ohaus I150-S Indicator. Ohaus I150-S Indicator User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Instruction Manual
I150 Electronic Indicator
Models I150-P and I150-S
Ohaus CorporationOhaus Corporation
Ohaus CorporationOhaus Corporation
Ohaus Corporation
29 Hanover Road
Florham Park NJ
07932-0900
Vista de página 0
1 2 3 4 5 6 ... 75 76

Resumo do Conteúdo

Página 1 - Instruction Manual

Instruction ManualI150 Electronic IndicatorModels I150-P and I150-SOhaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporati

Página 2

10RS-232 ConnectionsRS-232 ConnectionsRS-232 ConnectionsRS-232 ConnectionsRS-232 ConnectionsUsing a small screwdriver, connect theRS-232 interface cab

Página 3 - Classifications

11Digital Output ConnectionsDigital Output ConnectionsDigital Output ConnectionsDigital Output ConnectionsDigital Output ConnectionsDigital outputs ar

Página 4 - TABLE OF CONTENTS

12Turning the I150 ONTurning the I150 ONTurning the I150 ONTurning the I150 ONTurning the I150 ONAfter all connections have been made, plug in the pow

Página 5

13Numeric Keypad;used to enternumeric valueswhen applicable.Switches display from one loadreceiver to another. Stepsbackward through menu se-lections.

Página 6

14TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:TO ACCESS THE MAIN MENU:Press FNCT, then press SETP.

Página 7

15Resetto factorydefaultsALEnter value0, 1, 2 or 3StbEnter value0.5, 1 or 3Selectactive unitsAT0.5, 1, 3 orOFFCustom UnitsExp. MantissaEnter Entervalu

Página 8 - Load Receiver Connections

16MAIN MENUMAIN MENUMAIN MENUMAIN MENUMAIN MENUDisplayed SubmenuDisplayed SubmenuDisplayed SubmenuDisplayed SubmenuDisplayed SubmenuDescriptionDescrip

Página 9

17To select an item from a menu:To select an item from a menu:To select an item from a menu:To select an item from a menu:To select an item from a men

Página 10

18SETUP SUBMENUSETUP SUBMENUSETUP SUBMENUSETUP SUBMENUSETUP SUBMENUThe Setup submenu is used to view or change the parameters outlined in the followin

Página 11 - Digital Output Connections

19Legal For TradeLegal For TradeLegal For TradeLegal For TradeLegal For TradeThis parameter can be set to ON or OFF.Selecting ON automatically sets ce

Página 12

2The exclamationpoint within the tri-angle is a warningsign alerting you ofimportant instruc-tions accompany-ing the product.NOTE:NOTE:NOTE:NOTE:NOTE:

Página 13 - Key Functions

20Number of Load ReceiversNumber of Load ReceiversNumber of Load ReceiversNumber of Load ReceiversNumber of Load ReceiversThe I150 is configured for o

Página 14

21Calibration UnitCalibration UnitCalibration UnitCalibration UnitCalibration UnitThe indicator can be calibrated usingpounds or kilograms; no other u

Página 15

22GraduationsGraduationsGraduationsGraduationsGraduationsThis parameter specifies the incrementsin which the last digit of the display willcount, and

Página 16 - How To Use Menus

23Linearization PointLinearization PointLinearization PointLinearization PointLinearization PointThis parameter is used when 3-point lin-earization is

Página 17 - Load Receiver #1

24To select a parameter:Repeatedly press UPUP or DOWNuntil it is displayed,then press ENTER.SCALE SUBMENUMENUSCALE SUBMENUMENUSCALE SUBMENUMENUSCALE S

Página 18 - SETUP SUBMENU

25Reset to Factory DefaultsReset to Factory DefaultsReset to Factory DefaultsReset to Factory DefaultsReset to Factory DefaultsThis parameter is used

Página 19

26Stability RangeStability RangeStability RangeStability RangeStability RangeThe stability range specifies how much adisplayed weight may change (in g

Página 20

27Unit SelectionUnit SelectionUnit SelectionUnit SelectionUnit SelectionThe I150 provides four weighing unitswhich may be used for weighing opera-tion

Página 21 - Enter Full Scale Point

28Auto-Zero TrackingAuto-Zero TrackingAuto-Zero TrackingAuto-Zero TrackingAuto-Zero TrackingAuto-Zero tracking minimizes the effectsof temperature cha

Página 22

29Entering a Conversion FactorEntering a Conversion FactorEntering a Conversion FactorEntering a Conversion FactorEntering a Conversion FactorConversi

Página 23

3PREFACEPREFACEPREFACEPREFACEPREFACEThe I150 Electronic Indicator is a highly versatile device which is designed for a varietyof applications. It can

Página 24 - SCALE SUBMENUMENU

30Conversion Factor ExamplesConversion Factor ExamplesConversion Factor ExamplesConversion Factor ExamplesConversion Factor ExamplesCustom unit conver

Página 25

31Average Display CycleAverage Display CycleAverage Display CycleAverage Display CycleAverage Display CycleAverage display cycle is used for animalwei

Página 26 - Stability Range

32Set PointSet PointSet PointSet PointSet PointSet point is used to enable checkweigh-ing, filling or emptying for operation. Ena-bling one of these m

Página 27 - Unit Selection

33To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:To Enter DRIBBLE and PREACT:1. With

Página 28 - ENTERENTER

348. To change the value, use the nu-meric keypad.For emptying processes, make thedisplayed value negative by pressingFUNC then CLRR.9. To accept the

Página 29

35Retain Zero DataRetain Zero DataRetain Zero DataRetain Zero DataRetain Zero Data“rEtAin” can be set to ON or OFF. Whenset to ON, zero data is saved

Página 30 - 0.0625 = 0.625 x 10

36CALIBRATION SUBMENUCALIBRATION SUBMENUCALIBRATION SUBMENUCALIBRATION SUBMENUCALIBRATION SUBMENUThe calibration submenu is used for two purposes: To

Página 31

37CalibrationCalibrationCalibrationCalibrationCalibrationBefore beginning, you must know thecalibration point that was entered in the“SEtUP” submenu,

Página 32 - LED Indicators

383. The display will show “buSY” whilethe I150 reads the first calibrationpoint, and then show “C XXXX” indi-cating the value of a load which mustbe

Página 33

397. Apply the required load to the loadreceiver, and then press ENTER.8. The display will show “buSY” whilethe I150 reads the last calibrationpoint.9

Página 34 - StoreStore

4TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSPAGEUNPACKING ...

Página 35

40RS-232 SUBMENURS-232 SUBMENURS-232 SUBMENURS-232 SUBMENURS-232 SUBMENUThe RS-232 submenu is used to configure the interface communication parameters

Página 36 - Example:

41To select a parameter:Repeatedly press UPUP or DOWNuntil it is displayed,then press ENTER.Baud RateBaud RateBaud RateBaud RateBaud RateBaud rate can

Página 37

42Sample Size (APW)Sample Size (APW)Sample Size (APW)Sample Size (APW)Sample Size (APW)(for Auxiliary Sample Scale)(for Auxiliary Sample Scale)(for Au

Página 38

43Non Printing Weight ValuesNon Printing Weight ValuesNon Printing Weight ValuesNon Printing Weight ValuesNon Printing Weight Valuesand Auto Print Tim

Página 39

4411. Enter the desired interval in seconds( maximum of 255) using the numerickeypad, then press ENTR.12. Press UPUP or DOWN to scroll to“End”.13. P

Página 40 - RS-232 SUBMENU

45To select display or block print:Press UPUP or DNDN to display thedesired setting, then press ENTR toreturn to the rS-232 submenu.Print Numeric Data

Página 41

46EndEndEndEndEndYou must select “End” to exit the rS-232submenu.1. Press ENTER when “End” is dis-played.2. “rS-232” will be displayed and themain m

Página 42

47Disabling Menu Changes forDisabling Menu Changes forDisabling Menu Changes forDisabling Menu Changes forDisabling Menu Changes forLegal For Trade In

Página 43

48Hole PlugClosing the CoverClosing the CoverClosing the CoverClosing the CoverClosing the CoverWhen all connections and settings havebeen made, close

Página 44

49WeighingWeighingWeighingWeighingWeighing1. Select the desired weighing unit .2. If necessary, press ZERO to obtain azero reading on the display.3. P

Página 45

5PAGERS-232 SUBMENU ... 40Baud Rate ...

Página 46

504. To view the combined weight of thematerial and the container (grossweight), press GROSS.Repeatedly pressing GROSS willcause the display to switch

Página 47 - Disable Changes

51View/Enter Time and DateView/Enter Time and DateView/Enter Time and DateView/Enter Time and DateView/Enter Time and DateThe I150 is equipped with an

Página 48 - Hole Plug

52Parts CountingParts CountingParts CountingParts CountingParts CountingParts counting enables you to place abatch of similar parts on the platformwhi

Página 49 - Indicator

53Enter the number of pieces using thenumeric keypad, then press PCSS.The indicator will use the sample asa reference for counting.The sample may be a

Página 50

54Subtractive Parts CountingSubtractive Parts CountingSubtractive Parts CountingSubtractive Parts CountingSubtractive Parts CountingThis method of par

Página 51 - View/Enter Time and Date

55Parts Counting With An Auxiliary Sample ScaleParts Counting With An Auxiliary Sample ScaleParts Counting With An Auxiliary Sample ScaleParts Countin

Página 52 - Parts Counting

56SetupSetupSetupSetupSetupRS-232 parameters for the I150, sample scale and printer/computer (if used) must beconfigured the same; baud rate, parity,

Página 53

57CheckweighingCheckweighingCheckweighingCheckweighingCheckweighingCheckweighing enables you to compareunknown weights to a target weight. Byentering

Página 54 - Subtractive Parts Counting

58Filling and Emptying ProcessesFilling and Emptying ProcessesFilling and Emptying ProcessesFilling and Emptying ProcessesFilling and Emptying Process

Página 55 - RS-232 Connections

59TOLERANCE - set point 2TOLERANCE - set point 2TOLERANCE - set point 2TOLERANCE - set point 2TOLERANCE - set point 21. Enter the value using the nume

Página 56

6UNPACKINGUNPACKINGUNPACKINGUNPACKINGUNPACKINGVerify that your indicator was shippedwith the following items:• I150-P or I150-S indicator• power cord•

Página 57 - Checkweighing

60Emptying Processes:Emptying Processes:Emptying Processes:Emptying Processes:Emptying Processes:1. Enter a value equal to 10% of thetarget weight for

Página 58

61Animal WeighingAnimal WeighingAnimal WeighingAnimal WeighingAnimal WeighingBefore beginning this procedure, makesure the number of sample readings t

Página 59 - Suspended

62Storing Tare Values With ID Codes:Storing Tare Values With ID Codes:Storing Tare Values With ID Codes:Storing Tare Values With ID Codes:Storing Tare

Página 60

63Using Stored Average Piece Weights:Using Stored Average Piece Weights:Using Stored Average Piece Weights:Using Stored Average Piece Weights:Using St

Página 61

64The following will be output via theRS-232 interface:XX:XX:XX (time) *XX/XX/XX (date) *ID: XXXXXX (ID code)IN: X.XXXX lb (original load)OUT: X.XXXX

Página 62 - Press RECALL

65RS-232 INTERFACERS-232 INTERFACERS-232 INTERFACERS-232 INTERFACERS-232 INTERFACETerminal Block ConnectionsTerminal Block ConnectionsTerminal Block C

Página 63

66RS-232 COMMAND TABLERS-232 COMMAND TABLERS-232 COMMAND TABLERS-232 COMMAND TABLERS-232 COMMAND TABLE< or > switch load receivers; if dual lo

Página 64

67RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE (Continued)RS-232 COMMAND TABLE

Página 65 - RS-232 INTERFACE

68Output FormatsOutput FormatsOutput FormatsOutput FormatsOutput FormatsData output can be initiated in one of three ways: (1) By pressing PRINT; (2)

Página 66

69Block Data Output:Block Data Output:Block Data Output:Block Data Output:Block Data Output:When “bLoc” is selected for “Print” in the rS-232 submenu,

Página 67

7INSTALLATIONINSTALLATIONINSTALLATIONINSTALLATIONINSTALLATIONPower ConnectionsPower ConnectionsPower ConnectionsPower ConnectionsPower ConnectionsUsin

Página 68 - Output Formats

70SYMPTOMUnit will not turn on.Cannot rezero indicator,or will not re-zero whenturned on.Center of Zero display in-dicator erratic or does notappear w

Página 69

71SYMPTOMUnable to tare (tare keyor RS232 command)Unable to tare (keypadnumeric entry)Unable to retrieve storedID codes and data.Excessive weight read

Página 70 - TROUBLESHOOTING

72Error CodesError CodesError CodesError CodesError CodesErr 0: Invalid memory checksum. Checksum is verified every time I150 is turnedon. Check setup

Página 71 - TROUBLESHOOTING (Cont’d.)

73SPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSModel NumbersModel NumbersModel NumbersModel NumbersModel Numbers I150-P and

Página 72 - Error Codes

74REPLACEMENT PARTSREPLACEMENT PARTSREPLACEMENT PARTSREPLACEMENT PARTSREPLACEMENT PARTSOHAUSPART NO.Membrane Switch Panel 90835-00Display Filter Windo

Página 73 - SPECIFICATIONS

75CARE AND MAINTENANCECARE AND MAINTENANCECARE AND MAINTENANCECARE AND MAINTENANCECARE AND MAINTENANCEI150 indicators are washdown units designed for

Página 74

76Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (201) 377-9000,Fax: (201) 593-0359With offices worldwide.P/N 77223-01 R1099 © Oh

Página 75

86. After the connections have beenmade, fasten two cable ties (includedin the accessory kit) around the powercord as shown in the diagram. Thecable t

Página 76

9Installing “Gain Setting”Installing “Gain Setting”Installing “Gain Setting”Installing “Gain Setting”Installing “Gain Setting”Shorting JumpersShorting

Comentários a estes Manuais